Alarm
This guide will go over the layout for the settings pages of the DX and DL range of DVRs
Accessing the Menu - Using a remote
- Press the SETUP button on the remote and enter the password (default is eagle)
Accessing the Menu - Using Touchscreen monitor
- Tap the screen to bring up the options along the bottom of the screen, then tap the Login icon in the bottom right corner (see image below)
Setup
Alarm
BASE
➢ Base Speed alarm
➢ Base Speed alarm
Name: The current name is over speed
Enable: Enable or disable, tick to enable
Alarm type: It includes the following types, important and general.
Trigger:
Enable: Enable or disable, tick to enable
Alarm type: It includes the following types, important and general.
Trigger:
Over speed pre alarm difference: To set the pre alarm data. For example, if speed is 60 km/hour, and over speed pre alarm difference is 10 km /hour, TSS sends over speed alarm broadcast and records when it reaches 50 km/h.
Speed: It is the alarm speed.
Alarm duration: Alarm output duration
Linkage: When alarm triggered, link to other business operation.
Speed: It is the alarm speed.
Alarm duration: Alarm output duration
Linkage: When alarm triggered, link to other business operation.
Channel: Link to recording channel, optional.
Post recording: It means the recording duration after the alarm has been removed.
Lock: Enable to link recording lock when there is alarm.
3G network: When it is set as sensor trigger dial mode, it enables 3G network as it triggers alarm.
Linkage I/O output: Enable to link alarm output when alarm is triggered.
Output delay time: It means the alarm output duration after alarm is removed.
Alarm upload: Enable to upload to platform.
Linkage screen: Enable to link the channel to show full image when there is alarm. ( Depends on the MDVR model, display split 1/4/9 optional.)
PB alarm duration: It means the available alarm duration after urgent alarm is removed.
Alarm snap: Enable to link snap.
Post recording: It means the recording duration after the alarm has been removed.
Lock: Enable to link recording lock when there is alarm.
3G network: When it is set as sensor trigger dial mode, it enables 3G network as it triggers alarm.
Linkage I/O output: Enable to link alarm output when alarm is triggered.
Output delay time: It means the alarm output duration after alarm is removed.
Alarm upload: Enable to upload to platform.
Linkage screen: Enable to link the channel to show full image when there is alarm. ( Depends on the MDVR model, display split 1/4/9 optional.)
PB alarm duration: It means the available alarm duration after urgent alarm is removed.
Alarm snap: Enable to link snap.
➢ Base Panic alarm
Enable: Enable to panic button.
Alarm type: Important type and general type optional.
Trigger: Click any button to delay the time till it reaches the setting time to alarm
Linkage: When alarm is triggered, link to business operation.
Channel: Link to recording channel, optional.
Post recording: It means t he recording duration after the alarm has been removed.
Lock: Enable to link recording lock when there is alarm.
3G network: When it is set as sensor trigger dial mode, it enables 3G network as it triggers alarm.
Linkage IO output: Enable to link alarm output when alarm is triggered.
Output delay time: It means the alarm output duration after alarm is removed.
Alarm upload: Enable to upload to platform.
Linkage screen: Enable to link the channel to show full image when there is alarm. (Depends on the
MDVR model, display split 1/4/9 optional.)
PB alarm duration: It means the available alarm duration after urgent alarm is removed.
Alarm snap: Enable to link snap.
Post recording: It means t he recording duration after the alarm has been removed.
Lock: Enable to link recording lock when there is alarm.
3G network: When it is set as sensor trigger dial mode, it enables 3G network as it triggers alarm.
Linkage IO output: Enable to link alarm output when alarm is triggered.
Output delay time: It means the alarm output duration after alarm is removed.
Alarm upload: Enable to upload to platform.
Linkage screen: Enable to link the channel to show full image when there is alarm. (Depends on the
MDVR model, display split 1/4/9 optional.)
PB alarm duration: It means the available alarm duration after urgent alarm is removed.
Alarm snap: Enable to link snap.
➢ Base IO alarm interface:
Enable: Enable the sensor alarm.
Alarm type: Important type and general type optional.
Trigger: Low and high optional. It triggers alarm when it is low as default.
Linkage: When alarm is triggered, link to business operation.
Channel: Link to recording channel, optional.
Post recording: It means t he recording duration after the alarm has been removed.
Lock: Enable to link recording lock when there is alarm.
3G network: When it is set as sensor t rigger dial mode, it enables 3G network as it triggers alarm.
Linkage IO output: Enable to link alarm output when alarm is triggered.
Output delay time: It means the alarm output duration after alarm is removed.
Alarm upload: Enable to upload to platform.
Linkage screen: Enable to link the channel to show full image when there is alarm. (Depends on the
MDVR model, display split 1/4/9 optional.)
PB alarm duration: It means the available alarm duration after urgent alarm is removed.
Alarm snap: Enable to link snap.
Post recording: It means t he recording duration after the alarm has been removed.
Lock: Enable to link recording lock when there is alarm.
3G network: When it is set as sensor t rigger dial mode, it enables 3G network as it triggers alarm.
Linkage IO output: Enable to link alarm output when alarm is triggered.
Output delay time: It means the alarm output duration after alarm is removed.
Alarm upload: Enable to upload to platform.
Linkage screen: Enable to link the channel to show full image when there is alarm. (Depends on the
MDVR model, display split 1/4/9 optional.)
PB alarm duration: It means the available alarm duration after urgent alarm is removed.
Alarm snap: Enable to link snap.
VIDEO
➢ Video Video loss
➢ Video Video loss
Enable: Enable the video loss.
Alarm type: Important type and general type optional.
Trigger:
Video loss set: It includes all video channels that can be selected.
Set period: Set the checking period when video loss alarm is triggered.
Linkage: When alarm is triggered, link to business operation.
Set period: Set the checking period when video loss alarm is triggered.
Linkage: When alarm is triggered, link to business operation.
Channel: Link to recording channel, optional.
Post recording: It means the recording duration after the alarm has been removed.
Lock: Enable to link recording lock when there is alarm.
3G network: When it is set as sensor trigger dial mode, it enables 3G network as it triggers alarm.
Linkage IO output: Enable to link alarm output when alarm is triggered.
Output delay time: It means the al arm output duration after alarm is removed.
Alarm upload: Enable to upload to platform.
Linkage screen: Enable to link the channel to show full image when there is alarm. (Depends on the
MDVR model, display split 1/4/9 optional.)
PB alarm duration: It mean s the available alarm duration after urgent alarm is removed.
Alarm snap: Enable to link snap.
Post recording: It means the recording duration after the alarm has been removed.
Lock: Enable to link recording lock when there is alarm.
3G network: When it is set as sensor trigger dial mode, it enables 3G network as it triggers alarm.
Linkage IO output: Enable to link alarm output when alarm is triggered.
Output delay time: It means the al arm output duration after alarm is removed.
Alarm upload: Enable to upload to platform.
Linkage screen: Enable to link the channel to show full image when there is alarm. (Depends on the
MDVR model, display split 1/4/9 optional.)
PB alarm duration: It mean s the available alarm duration after urgent alarm is removed.
Alarm snap: Enable to link snap.
ADVANCE
Enable: Enable the ACC alarm.
Trigger: Set the threshold value of X/Y/Z.
Linkage: When alarm is triggered, link to business operation.
Post recording: It means t he recording duration after the alarm has been removed.
Lock: Enable to link recording lock when there is alarm.
3G network: When it is set as sensor trigger dial mode, it enables 3G network as it triggers alarm.
Linkage IO output: Enable to link alarm output when alarm is triggered.
Output delay time: It means the alarm output duration after alarm is removed.
Alarm upload: Enable to upload to platform.
Linkage screen: Enable to link the channel to show full image when there is alarm. (Depends on the
MDVR model, display split 1/4/9 optional.)
PB alarm duration: It means the available alarm duration after urgent alarm is removed.
Alarm snap: Enable to link snap.
X:0.0, Y:0.0, Z:0.0: The real time acceleration information.
Files | ||
---|---|---|
DataImage68.png 67 KB |
||
DataImage17.png 20 KB |
||
DataImage92[1].png 24 KB |
||
DataImage76.png 28 KB |
||
DataImage20.png 65 KB |
||
DataImage77.png 17 KB |
||
DataImage45.png 24 KB |
||
DataImage14.png 28 KB |
||
DataImage35.png 86 KB |
||
DataImage4.png 18 KB |
||
DataImage2.png 24 KB |
||
DataImage70.png 28 KB |
||
DataImage84.png 59 KB |
||
DataImage1.png 13 KB |
||
DataImage19.png 22 KB |
||
DataImage65.png 24 KB |
||
DataImage92.png 28 KB |
||
DataImage47.png 57 KB |
||
DataImage59.png 12 KB |
||
DataImage85.png 24 KB |
||
DataImage23.png 28 KB |